SUSPENDED FLOORS
When fitting ECOFLEX cable to a timber sub-floor it is essential that standard precautions to stabilise the floor are taken to prevent floor movement. All chipboard & timber floorboards must be covered with either ECOMAX insulated tile backer board or 18mm Plywood.

TOP LAYER - Tile/Stone floor
SECOND LAYER - Tile Adhesive/Self leveling compound
THIRD LAYER - ECOFLEX Cable
FOURTH LAYER - ECOMAX Thermal Insulation
FIFTH LAYER - Suspended Timber Floor
CONCRETE FLOORS
For optimal performance it is recommended before laying ECOFLEX cable, a layer of ECOMAX insulated tile backer board is fitted. This will minimise heat losses & ensure quicker heat-up times for the floor. ECOFLEX can be laid directly onto an uninsulated floor, however this will increase running costs & heat-up times.

TOP LAYER - Tile/Stone floor
SECOND LAYER - Tile Adhesive/Self leveling compound
THIRD LAYER - ECOFLEX Cable
FOURTH LAYER - ECOMAX Thermal Insulation
FIFTH LAYER - Concrete Sub Floor